• Calibration solution specification: for 2764?S/cm
• Quantity: 480mL
• Model number: ECCON2764BT …
• Calibration solution specification: for 5.0mS/cm
• Quantity: 480mL
• Model number: ECCON5000BT …
• Calibration solution specification: for 500?S/cm
• Quantity: 480mL
• Model number: ECCON500BT …
• Calibration solution specification: for 84?S/cm
• Quantity: 480mL
• Model number: ECCON84BT …
• For single junction pH electrode
• Capacity (mL): 480
• Model number: ECRE001 …
• Model number: ORPSENSORDJ
• Replacement electrode for ORPTestr10
• Waterproof type
• It is large display screen (27?21*mm*) which is easy…
• pH measurement range: 1 - 13pH
• Temperature measuring range: 0 - 50?
• Material: PMP resin
• Measuring section size: f12…
• pH measurement range: 1 - 13pH
• Temperature measuring range: 0 - 80?
• Material: PMP resin
• Measuring section size: f12…
• Model number: pHTestr10
• Measurement range (pH): -1.0 to +15.0
• Resolution (pH): 0.1
• Calibration: 3 points (USA/pH4.01, 7.00, 10.01 or…
• Model number: pHTestr20
• Measurement range (pH): -1.00 to +15.00
• Resolution (pH): 0.01
• Calibration: 3 points (USA/pH4.01, 7.00, 10.01 or…
• Model number: PHSENSOR03DJ
• Replacement electrode
• Operating temperature range: 0 - 50?
• Size: f20mm
• Waterproof type
• Exchange of sensor…
• Model number: EC-pH5+
• Item to be measured: pH, ?
• Measurement range: pH/1 - 13, Temperature/0 - 80?, ORP/-1000mV to…
• Model number: EC-pH6+
• Item to be measured: pH, ?, mV
• Measurement range: pH/1 - 13, Temperature/0 - 80?, ORP/-1000mV…
• Resolution (NTU): 0.01/0.1/1
• Model number: TN100IR
• Able to be automatically calibrated at touch of button.
• Equipped with…
• Accuracy: +/- 6%
• Measurement target: Water
• Pressure resistance: 0.4MPa
• Operating temperature range: 0 to +60?
• Flowmeter material: PC (polycarbonate)
•…
• Accuracy: +/- 6%
• Measurement target: Water
• Pressure resistance: 0.4MPa
• Operating temperature range: 0 to +60?
• Flowmeter material: PC (polycarbonate)
•…
• Accuracy: +/- 6%
• Measurement target: Water
• Pressure resistance: 0.4MPa
• Operating temperature range: 0 to +60?
• Flowmeter material: PC (polycarbonate)
•…
• Measuring method: pH/glass electrode method, ORP/platinum electrode method, Ion/ion electrode method, Electric conductivity/AC 2 electrode method, Dissolved oxygen/diaphragm type…
• Model number: AS824
• Measurement range (dB): A/C characteristic 30 to 130
• resolution (dB): 0.1
• Frequency range:…
• Model number: AS804
• Measurement range (dB): A characteristic 30 to 130
• resolution (dB): 0.1
• Frequency range:…